W67-2
Base edge profile SOKA-FIX-DUEWith cranked drip edge and plastic nails

Die APU-Base edge profile SOKA-FIX-DUE W67-2

The APU base edge profile SOKA-FIX-DUE is used in compound heat insulation systems as the bottom termination of the wall insulation. Dependent on insulating material thickness, the base edge profile is pushed in in flexible ways between perimeter insulation and wall insulation. Where insulating material thick- nesses differ, the base edge profile can in each instance be extended by 50 mm using the APU extension for W66 (Z23). The base edge profile forms an exact plaster edge with drip nose.

The base edge profile SOKA-FIX-DUE, with its cranked contour, ensures that water is accurately guided away. There is a fabric window reveal bead welded onto the profile. Each bar has a fabric overhang on one side of 10cm in the lengthways direction. For fixing the profile in place, pre-punched holes for the plastic nails (Z21) are integrated in the plaster bar. The included plug connectors (Z13) and inner and outer corners (Z18 - 2) enable the profiles to be joined and fitted very precisely. What is created after completion of the plastering work is a clean termination of the plaster.

Design

Base edge profile SOKA-FIX-DUE, With cranked drip edge and plastic nails
W67-2-2000
Length2.0 m
Packaging unit25 bars = 50 m
Weight (per PU)10.2 kg

Features

 
Material
  • Rigid PVC manufactured under DIN 16941
Mesh
  • Min. 160 g/m2 approved for compound heat insulation systems 12.5 cm wide – MW 4x4mm
  • Ultrasonic welded
Accessories
  • Z13-0000 Plug connectors (1 bag)
  • Z18-2-1010i Internal corners (2 pieces)
  • Z18-2-1010a External corners (4 pieces)
  • Z21-2050 Plastic nails (1 bag)
Optional accessories
  • For installing the perimeter insulation later:
  • Z16-0060 Mounting bracket 60 mm
  • Z16-0120 Mounting bracket 120 mm
  • Z20-2005 Mounting rail 50 mm
  • Z20-2010 Mounting rail 100 mm
  • Z20-2016 Mounting rail 160 mm
  • For installation without perimeter insulation (insulation material thickness up to 150 mm):
  • Z20-2005 Mounting rail 50 mm
  • Z20-2010 Mounting rail 100 mm
  • For insulating material extension:
  • Z23-2000 extension for W66 2.0 m

Important notes

Other applicationsAny applications not clearly described in the documents may be implemented only after consultation with the plaster or ETICS manufacturer.
Perimeter insulationWhere the insulating material thickness is 150 mm or more, perimeter insulation is required.
For retrospective installation of perimeter insulation
see Z16 and Z20 product documents
For installation with no perimeter insulation
see Z20 product documents

Details

Sectional drawing in mm

 

Application drawing